Any management card, powernet agent, or masterswitch unit can send traps to an nms when specific events occur. After you add the powernet mib to a standard snmp mib browser, you can use that browser for snmp access to the switched rack pdu. The location of the label as well as letter and number sequences will vary by model and product type. Closed vrillusions wants to merge 1 commit into librenms. Basically, is a 10 mbps ethernet adapter which allows the ups to communicate via snmp instead of having to use a serial cable connected to one computer. Powernetmib provided by american power conversion corp. Activexperts network monitor supports american power conversion corp mib files, to monitor. Powernet mib provided by american power conversion corp powernet mib file content. The apc ap9605 powernet snmp adapter is a smartslot accessory which was sold by apc for their ups products it has since been discontinued in favor of newermore advanced cards. The wizard is available as a free download from the apc by schneider electric website at. Snmp oids required for rack pdu 2g products ap86xx. The wizard is available as a free download from the apc website at.
The node in this entry will receive traps defined in apc powernet mib, if this oid is set to yes. Hi jeff, the smx2000rmlv2unc you mentioned ships with one of our ap9631 network management cards preinstalled. I tried updating my downloads for my apc7920 and apc7921 pdus. Apc inline voltage and ups output voltage in vac 1,2,4 use snmp get for data input 3 gets data from a shell script due to the fact that runtime is in timeticks not gauge so require a little conversion to minutes, otherwise its also getting the input data through snmpget. In order to find the oids i downloaded the powernet mib from the apc website and used manageengine mibbrowser free tool then loaded the mib and looked for the oid, also when creating the custom poller you can test it right there to see if it returns the correct value. Integrate apc upss into leading server,enterprise, building and scada management systems. We do however strongly recommend acquiring mibs directly from your hardware vendors to ensure you importing the newest versions of the files. Script to control an apc masterswitch pdu to reset an. Firmware upgrades for all supported apc offers, bringing the latest supported features to end users. Created by request from local ups admin man u r sooo lazzy for zabbix. The ups from apc has a network interface and additional a measurement modul for environment. Ive been meaning to rewrite an internal tool we i use at work to manage our apc pdus.
The import with the integrated utility seems to work, as does the the parsing, since ome notifies me that its successfully parsed 753 traps from the mib file which, n. Communitybased gpllicensed network monitoring system librenmslibrenms. These mibs management information base have been submitted by users of whatsup gold. Only if a validnewagentcodeimage 1 is found will the agent reboot the powernet adaoter and invoke the loader to load and save new code into the flash. They are available for you to download and install into whatsup gold.
Download the mib file you need, for example, powernet mib. Basics rack pdus group their outlets in banks and report per bank current load in amperes. Monitoring your apc ups with the tick stack and grafana. American power conversion corp snmp powernetmib file. To do this im going to use parts of the tick stack, primarily telegraf for polling and data collection and influxdb for backend database heres a short introduction on those modules. Apc powernet mib hewlett packard enterprise community. Download if you dare 3mb zipped file containing almost 20mb of mibs from vendors such as cisco, hp, microsoft, novell, xyplex, racal, banyan, att, cabletron, plaintree and more. Apc is a full service provider of power management systems and supplies from surge protectors to backup batteries to cooling solutions and more.
Much to my surprise, there seemed to be lack of good snmp resources including how to install mibs and determine the oids i needed. Please refer to knowledge base fa156148 for additional information and recommendations. For assistance with this or any other american power conversion product, contact apc worldwide customer support. The mib reference guide, available on the network management card cd and on the apc web site. Apc ap9605 powernet snmp adapter username and password. For information on specific oids, use a mib browser to view their definitions and available values. Smt750i actually theyre fujitsu branded fjt750i all upses have an ap9630 management card. Reference guide 6 associated documents this guide describes how to use the powernet mib, only.
Once mcontrolrestartagent is set to loadandexecutenewagent 3, powernet adapter will start to load the remote image file, for authentication only, instead of saving the code into flash memory. Release notes netbotz rack monitor 250 schneider electric. By downloading, installing, loading, copying, or otherwise using the software, you. Since pdu reports its nominal line to line voltage and power factor, current load can be managed too as power watts load. How to configure solarwinds to sent alerts for apc. The snmp getnext request is used to query a device and take snmp data from a device. Apcschneider powernet mib import issue in openmanage. How can i monitor additional counters of my apc devices. Rack ats ap44xx release notes schneider electric documents. Netbotz has a dedicated snmp mib excluding netbotz 200250.
Activexperts network monitor download ships with advanced snmpmib tools. For information about the apc product you want to manage using the powernet mib, refer to the appropriate apc users guide or owners manual, for that product. The powernet mib supports all apc network enabled devices except netbotz. However, if these prtg standard libraries are not sufficient for your needs, you can use the. With the cheap addition of a network module snmp v2v3 support is easily added to this unit the next step is setting up monitoring.
Im not skilled perl programmer, this is my first perl script i ever wrote. These oids definitely work with the apc ap9617 management card which plugs in the back of apc devices. You will need a registration for apc to download an mib file. Title page powernet snmp management information base. This article applies to prtg network monitor 12 or later. Script to control an apc masterswitch pdu to reset an outlet when the network stops working apc pdu monitor instructions. Release notes network management card for pdu schneider. You will assign an ip address, subnet mask and default gateway to the card and it will be accessible via the web, ftp or telnet to check statuses. We are wanting to read snmp data for the following upses.
The snmpwalk command is used because it allows the user to chain getnext requests together without having to enter unique commands for each and every oid or node within a subtree. I asked apc about it, and they had me download a slightly older mib. Im getting alot of genericunregistered traps from the 2 apc smart3000 units. Powernetmib provided by american power conversion corp powernetmib file content. Also contains a huge number of rfc mibs click here to see the complete list. Recently i acquired a second hand apc smartups 3000. In the hierarchical structure of the powernet mib, the apc category of oids is at the top, and individual oids are in specific oid categories or within specific oid tables. Most network devices and programs ship with socalled mib files to describe the parameters and meanings i. By saying just like a book, apc means, for example, that the powernet. For reason unclear to me both our upss starts to report 1 as device temperature. Unlimited copies of the powernet mib may be used in conjunction with any.